Problem: |
Probable Cause: |
Solution: |
Yield Monitor is not showing up as available |
- Yield Monitor is not powered on
- Yield Monitor is already connected to a different mobile device
- Bluetooth© radio may not have initialized
- The mobile device is not detecting the Yield Monitor
|
- Confirm power to the Yield Monitor (LED is green if a Yield Monitor 2.0)
- Confirm no other devices
are currently paired to Yield Monitor
- Reboot the Yield Monitor by powering on and off
- Toggle Bluetooth© on
and off on the device
|
Yield Monitor connection fails |
- Interruption of Bluetooth© connection
- Mobile App was unable
to retrieve settings from the Yield Monitor
- The Yield Monitor did
not initialize
|
- Try reconnecting, if it does not connect on first try this is not the root problem
- Reboot by powering
the Yield Monitor on and of
|
Mobile App loses connection to Yield Monitor during operation |
|
- Do not use a cigarette light as a power source
- If using T-Splice connectors found in kit, ensure they are properly snapped down
- Ensure all connectors are fully snapped together and the 15 pin connector attached to the Data Logger is properly fastened
|
Firmware update fails |
- Mobile device failed data transmit
|
- Do not close the application while updating, let update complete before navigating away
- If update continues to fail close the app, reboot the Yield Monitor and try again
|
Firmware update requires re-doing |
- Firmware update encountered error
|
- Turn the combine’s power off for 60 seconds and attempt to reconnect to the Yield Monitor and continue with firmware updates
|